FN01 Series

Nylon Fitting, Quick Type, Straight Type (V0 / V2)

Nylon Fitting - Quick Type (FN01 Series) has been certified according to UL1696 and CSA C22.2
No.227.3 standard by mating with Nonmetallic Mechanical Protection Tubing (PAFS). The fitting is produced with Polyamide (PA) and designed by considering easy installation and also good mechanical strength. Further features of attrition resistance, fire retardant, resist low temperature and UV make nylon fitting be able to use in controlled or rough environments.

For locations existing constant vibration, FN02 & FN04 series with metal thread are recommended.

▶▶ Assembly of Flexible Corrugated Tubing and FN01 Quick Fitting (youtube)

Features
  • Material:PA66 (UL94 V-0), PA6 (UL94 V-2)
  • Thread System:NPT, M, PG & G
  • Temperature Range:-40℃~+120℃
  • IP Rating:IP 66
  • Flammability Rating:UL94 V-0, UL94 V-2
  • UV Resistance:Yes
  • Environmental Protection:RoHs Compliance, Halogen Free
  • Certificate:cRUus (File No. E491228), CE
Specification
NPT Thread
Nominal Conduit Size Nominal Conduit Size NPT Thread Part Number (V0 / V2) Package/Box (pcs) Weight/Box (kg) Certificate Mated With
10 1/4 1/4" FN0110-NPT1/4-V0
FN0110-NPT1/4-V2
660 3.2 NONMETALLIC MECHANICAL PROTECTION TUBING (UL 1696)
13 5/16 1/2" FN0113-NPT1/2-V0
FN0113-NPT1/2-V2
400 3.5 NONMETALLIC MECHANICAL PROTECTION TUBING (UL 1696)
16 3/8 1/2" FN0116-NPT1/2-V0
FN0116-NPT1/2-V2
300 2.8 NONMETALLIC MECHANICAL PROTECTION TUBING (UL 1696)
21 1/2 1/2" FN0121-NPT1/2-V0
FN0121-NPT1/2-V2
240 2.8 NONMETALLIC MECHANICAL PROTECTION TUBING (UL 1696)
28 3/4 3/4" FN0128-NPT3/4-V0
FN0128-NPT3/4-V2
150 2.6 NONMETALLIC MECHANICAL PROTECTION TUBING (UL 1696)
34 1 1" FN0134-NPT1-V0
FN0134-NPT1-V2
120 3.0 NONMETALLIC MECHANICAL PROTECTION TUBING (UL 1696)
42 1-1/4 1-1/4" FN0142-NPT1-1/4-V0
FN0142-NPT1-1/4-V2
60 2.1 NONMETALLIC MECHANICAL PROTECTION TUBING (UL 1696)
54 2 2" FN0154-NPT2-V0
FN0154-NPT2-V2
54 3.6 NONMETALLIC MECHANICAL PROTECTION TUBING (UL 1696)

M Thread
Nominal Conduit Size Nominal Conduit Size M Thread Part Number (V0 / V2) Package/Box (pcs) Weight/Box (kg) Certificate Mated With
10 1/4 M12 FN0110-M12-V0
FN0110-M12-V2
660 3.2 NONMETALLIC MECHANICAL PROTECTION TUBING (UL 1696)
13 5/16 M16 FN0113-M16-V0
FN0113-M16-V2
400 3.5 NONMETALLIC MECHANICAL PROTECTION TUBING (UL 1696)
16 3/8 M20 FN0116-M20-V0
FN0116-M20-V2
300 2.8 NONMETALLIC MECHANICAL PROTECTION TUBING (UL 1696)
21 1/2 M20 FN0121-M20-V0
FN0121-M20-V2
240 2.8 NONMETALLIC MECHANICAL PROTECTION TUBING (UL 1696)
28 3/4 M25 FN0128-M25-V0
FN0128-M25-V2
150 2.6 NONMETALLIC MECHANICAL PROTECTION TUBING (UL 1696)
34 1 M32 FN0134-M32-V0
FN0134-M32-V2
120 3.0 NONMETALLIC MECHANICAL PROTECTION TUBING (UL 1696)
42 1-1/4 M40 FN0142-M40-V0
FN0142-M40-V2
60 2.1 NONMETALLIC MECHANICAL PROTECTION TUBING (UL 1696)
54 2 M63 FN0154-M63-V0
FN0154-M63-V2
54 3.6 NONMETALLIC MECHANICAL PROTECTION TUBING (UL 1696)

PG Thread
Nominal Conduit Size Nominal Conduit Size PG Thread Part Number (V0 / V2) Package/Box (pcs) Weight/Box (kg) Certificate Mated With
10 1/4 PG7 FN0110-PG7-V0
FN0110-PG7-V2
660 3.2 NONMETALLIC MECHANICAL PROTECTION TUBING (UL 1696)
13 5/16 PG9 FN0113-PG9-V0
FN0113-PG9-V2
400 3.5 NONMETALLIC MECHANICAL PROTECTION TUBING (UL 1696)
16 3/8 PG11 FN0116-PG11-V0
FN0116-PG11-V2
300 2.8 NONMETALLIC MECHANICAL PROTECTION TUBING (UL 1696)
21 1/2 PG16 FN0121-PG16-V0
FN0121-PG16-V2
240 2.8 NONMETALLIC MECHANICAL PROTECTION TUBING (UL 1696)
28 3/4 PG21 FN0128-PG21-V0
FN0128-PG21-V2
150 2.6 NONMETALLIC MECHANICAL PROTECTION TUBING (UL 1696)
34 1 PG29 FN0134-PG29-V0
FN0134-PG29-V2
120 3.0 NONMETALLIC MECHANICAL PROTECTION TUBING (UL 1696)
42 1-1/4 PG36 FN0142-PG36-V0
FN0142-PG36-V2
60 2.1 NONMETALLIC MECHANICAL PROTECTION TUBING (UL 1696)
54 2 PG48 FN0154-PG48-V0
FN0154-PG48-V2
54 3.6 NONMETALLIC MECHANICAL PROTECTION TUBING (UL 1696)

G Thread
Nominal Conduit Size Nominal Conduit Size G Thread Part Number (V0 / V2) Package/Box (pcs) Weight/Box (kg) Certificate Mated With
10 1/4 1/4" FN0110-G1/4-V0
FN0110-G1/4-V2
660 3.2 NONMETALLIC MECHANICAL PROTECTION TUBING (UL 1696)
13 5/16 1/2" FN0113-G1/2-V0
FN0113-G1/2-V2
400 3.5 NONMETALLIC MECHANICAL PROTECTION TUBING (UL 1696)
16 3/8 1/2" FN0116-G1/2-V0
FN0116-G1/2-V2
300 2.8 NONMETALLIC MECHANICAL PROTECTION TUBING (UL 1696)
21 1/2 1/2" FN0121-G1/2-V0
FN0121-G1/2-V2
240 2.8 NONMETALLIC MECHANICAL PROTECTION TUBING (UL 1696)
28 3/4 3/4" FN0128-G3/4-V0
FN0128-G3/4-V2
150 2.6 NONMETALLIC MECHANICAL PROTECTION TUBING (UL 1696)
34 1 1" FN0134-G1-V0
FN0134-G1-V2
120 3.0 NONMETALLIC MECHANICAL PROTECTION TUBING (UL 1696)
42 1-1/4 1-1/4" FN0142-G1-1/4-V0
FN0142-G1-1/4-V2
60 2.1 NONMETALLIC MECHANICAL PROTECTION TUBING (UL 1696)
54 2 2" FN0154-G2-V0
FN0154-G2-V2
54 3.6 NONMETALLIC MECHANICAL PROTECTION TUBING (UL 1696)

Inquiry - KAIFLEX

View Picture
Selected Items
Estimate Purchasing Quantity
Estimate Purchasing Schedule
Nylon Fitting, Quick Type, Straight Type (V0 / V2)
Nylon Fitting - Quick Type (FN01 Series) has been certified according to UL1696 and CSA C22.2 No.227.3 standard by mating ...
Information of Contact Person
Company Information

( Including http:// )

Others

By submitting your contact information, you acknowledge that you consent to our processing data in accordance with the Privacy and Cookie Policy.